964 resultados para Flow-cytometry system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Paralytic shellfish poisoning is a toxic syndrome described in humans following the ingestion of seafood contaminated with saxitoxin and/or its derivatives. The presence of these toxins in shellfish is considered an important health threat and their levels in seafood destined to human consumption are regulated in many countries, as well as the levels of other chemically unrelated toxins. We studied the feasibility of immunodetection of saxitoxin and its analogs using a solid-phase microsphere assay coupled to flow cytometry detection in a Luminex 200 system. The technique consists of a competition assay where the toxins in solution compete with bead-bound saxitoxin for binding to an antigonyautoxin 2/3 monoclonal antibody (GT-13A). The assay allowed the detection of saxitoxin both in buffer and mussel extracts in the range of 2.2-19.7 ng/mL (IC(20)-IC(80)). Moreover, the assay cross-reactivity with other toxins of the group is similar to previously published immunoassays, with adequate detection of most analogs except N-1 hydroxy analogs. The recovery rate of the assay for saxitoxin was close to 100%. This microsphere-based immunoassay is suitable to be used as a screening method, detecting saxitoxin from 260 to 2360 µg/kg. This microsphere/flow cytometry system provided similar sensitivities to previously published immunoassays and provides a solid background for the development of easy, flexible multiplexing of toxin detection in one sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presence of paralytic shellfish poisoning (PSP), diarrheic shellfish poisoning (DSP) and amnesic shellfish poisoning (ASP) toxins in seafood is a severe and growing threat to human health. In order to minimize the risks of human exposure, the maximum content of these toxins in seafood has been limited by legal regulations worldwide. The regulated limits are established in equivalents of the main representatives of the groups: saxitoxin (STX), okadaic acid (OA) and domoic acid (DA), for PSP, DSP and ASP, respectively. In this study a multi-detection method to screen shellfish samples for the presence of these toxins simultaneously was developed. Multiplexing was achieved using a solid-phase microsphere assay coupled to flow-fluorimetry detection, based on the Luminex xMap technology. The multi-detection method consists of three simultaneous competition immunoassays. Free toxins in solution compete with STX, OA or DA immobilized on the surface of three different classes of microspheres for binding to specific monoclonal antibodies. The IC50 obtained in buffer was similar in single- and multi-detection: 5.6 ± 1.1 ng/mL for STX, 1.1 ± 0.03 ng/mL for OA and 1.9 ± 0.1 ng/mL for DA. The sample preparation protocol was optimized for the simultaneous extraction of STX, OA and DA with a mixture of methanol and acetate buffer. The three immunoassays performed well with mussel and scallop matrixes displaying adequate dynamic ranges and recovery rates (around 90 % for STX, 80 % for OA and 100 % for DA). This microsphere-based multi-detection immunoassay provides an easy and rapid screening method capable of detecting simultaneously in the same sample three regulated groups of marine toxins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Freshwater and brackish microalgal toxins, such as microcystins, cylindrospermopsins, paralytic toxins, anatoxins or other neurotoxins are produced during the overgrowth of certain phytoplankton and benthic cyanobacteria, which includes either prokaryotic or eukaryotic microalgae. Although, further studies are necessary to define the biological role of these toxins, at least some of them are known to be poisonous to humans and wildlife due to their occurrence in these aquatic systems. The World Health Organization (WHO) has established as provisional recommended limit 1 μg of microcystin-LR per liter of drinking water. In this work we present a microsphere-based multi-detection method for five classes of freshwater and brackish toxins: microcystin-LR (MC-LR), cylindrospermopsin (CYN), anatoxin-a (ANA-a), saxitoxin (STX) and domoic acid (DA). Five inhibition assays were developed using different binding proteins and microsphere classes coupled to a flow-cytometry Luminex system. Then, assays were combined in one method for the simultaneous detection of the toxins. The IC50's using this method were 1.9 ± 0.1 μg L−1 MC-LR, 1.3 ± 0.1 μg L−1 CYN, 61 ± 4 μg L−1 ANA-a, 5.4 ± 0.4 μg L−1 STX and 4.9 ± 0.9 μg L−1 DA. Lyophilized cyanobacterial culture samples were extracted using a simple procedure and analyzed by the Luminex method and by UPLC–IT-TOF-MS. Similar quantification was obtained by both methods for all toxins except for ANA-a, whereby the estimated content was lower when using UPLC–IT-TOF-MS. Therefore, this newly developed multiplexed detection method provides a rapid, simple, semi-quantitative screening tool for the simultaneous detection of five environmentally important freshwater and brackish toxins, in buffer and cyanobacterial extracts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydroxyapatite (HA)-based biocomposites have been widely investigated for a multitude of applications and these studies have been largely driven to improve mechanical properties (toughness and strength) without compromising cytocompatibility properties. Apart from routine cell viability/proliferation analysis, limited efforts have been made to quantify the fate processes (cell proliferation, cell cycle, and cell apoptosis) of human fetal osteoblast (hFOB) cells on HA-based composites, in vitro. In this work, the osteoblast cell fate process has been studied on a model hydroxyapatite-titanium (HA-Ti) system using the flow cytometry. In order to retain both HA and Ti, the novel processing technique, that is, spark plasma sintering, was suitably adopted. The cell fate processes of hFOBs, as evaluated using a flow cytometry, revealed statistically insignificant differences among HA-10 wt % Ti and HA and control (tissue culture polystyrene surface) in terms of osteoblast apoptosis, proliferation index as well as division index. For the first time, we provide quantified flow cytometry results to demonstrate that 10 wt % Ti additions to HA do not have any significant influence on the fate processes of human osteoblast-like cells, in vitro.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a light sheet based imaging flow cytometry technique for simultaneous counting and imaging of cells on a microfluidic platform. Light sheet covers the entire microfluidic channel and thus omits the necessity of flow focusing and point scanning based technology. Another advantage lies in the orthogonal detection geometry that totally cuts-off the incident light, thereby substantially reducing the background in the detection. Compared to the existing state-of-art techniques the proposed technique shows marked improvement. Using fluorescently-coated Saccharomyces cerevisiae cells we have recorded cell counting with throughput as high as 2,090 cells/min in the low flow rate regime and were able to image the individual cells on-the-go. Overall, the proposed system is cost-effective and simple in channel geometry with the advantage of efficient counting in operational regime of low laminar flow. This technique may advance the emerging field of microfluidic based cytometry for applications in nanomedicine and point of care diagnostics. Microsc. Res. Tech. 76:1101-1107, 2013. (c) 2013 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visualization of intracellular organelles is achieved using a newly developed high throughput imaging cytometry system. This system interrogates the microfluidic channel using a sheet of light rather than the existing point-based scanning techniques. The advantages of the developed system are many, including, single-shot scanning of specimens flowing through the microfluidic channel at flow rate ranging from micro-to nano- lit./min. Moreover, this opens-up in-vivo imaging of sub-cellular structures and simultaneous cell counting in an imaging cytometry system. We recorded a maximum count of 2400 cells/min at a flow-rate of 700 nl/min, and simultaneous visualization of fluorescently-labeled mitochondrial network in HeLa cells during flow. The developed imaging cytometry system may find immediate application in biotechnology, fluorescence microscopy and nano-medicine. (C) 2014 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Imaging flow cytometry is an emerging technology that combines the statistical power of flow cytometry with spatial and quantitative morphology of digital microscopy. It allows high-throughput imaging of cells with good spatial resolution, while they are in flow. This paper proposes a general framework for the processing/classification of cells imaged using imaging flow cytometer. Each cell is localized by finding an accurate cell contour. Then, features reflecting cell size, circularity and complexity are extracted for the classification using SVM. Unlike the conventional iterative, semi-automatic segmentation algorithms such as active contour, we propose a noniterative, fully automatic graph-based cell localization. In order to evaluate the performance of the proposed framework, we have successfully classified unstained label-free leukaemia cell-lines MOLT, K562 and HL60 from video streams captured using custom fabricated cost-effective microfluidics-based imaging flow cytometer. The proposed system is a significant development in the direction of building a cost-effective cell analysis platform that would facilitate affordable mass screening camps looking cellular morphology for disease diagnosis. Lay description In this article, we propose a novel framework for processing the raw data generated using microfluidics based imaging flow cytometers. Microfluidics microscopy or microfluidics based imaging flow cytometry (mIFC) is a recent microscopy paradigm, that combines the statistical power of flow cytometry with spatial and quantitative morphology of digital microscopy, which allows us imaging cells while they are in flow. In comparison to the conventional slide-based imaging systems, mIFC is a nascent technology enabling high throughput imaging of cells and is yet to take the form of a clinical diagnostic tool. The proposed framework process the raw data generated by the mIFC systems. The framework incorporates several steps: beginning from pre-processing of the raw video frames to enhance the contents of the cell, localising the cell by a novel, fully automatic, non-iterative graph based algorithm, extraction of different quantitative morphological parameters and subsequent classification of cells. In order to evaluate the performance of the proposed framework, we have successfully classified unstained label-free leukaemia cell-lines MOLT, K562 and HL60 from video streams captured using cost-effective microfluidics based imaging flow cytometer. The cell lines of HL60, K562 and MOLT were obtained from ATCC (American Type Culture Collection) and are separately cultured in the lab. Thus, each culture contains cells from its own category alone and thereby provides the ground truth. Each cell is localised by finding a closed cell contour by defining a directed, weighted graph from the Canny edge images of the cell such that the closed contour lies along the shortest weighted path surrounding the centroid of the cell from a starting point on a good curve segment to an immediate endpoint. Once the cell is localised, morphological features reflecting size, shape and complexity of the cells are extracted and used to develop a support vector machine based classification system. We could classify the cell-lines with good accuracy and the results were quite consistent across different cross validation experiments. We hope that imaging flow cytometers equipped with the proposed framework for image processing would enable cost-effective, automated and reliable disease screening in over-loaded facilities, which cannot afford to hire skilled personnel in large numbers. Such platforms would potentially facilitate screening camps in low income group countries; thereby transforming the current health care paradigms by enabling rapid, automated diagnosis for diseases like cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Flow cytometry, in combination with advances in bead coding technologies, is maturing as a powerful high-throughput approach for analyzing molecular interactions. Applications of this technology include antibody assays and single nucleotide polymorphism mapping. This review describes the recent development of a microbead flow cytometric approach to analyze RNA-protein interactions and discusses emerging bead coding strategies that together will allow genome-wide identification of RNA-protein complexes. The microbead flow cytometric approach is flexible and provides new opportunities for functional genomic studies and small-molecule screening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The timeline imposed by recent worldwide chemical legislation is not amenable to conventional in vivo toxicity testing, requiring the development of rapid, economical in vitro screening strategies which have acceptable predictive capacities. When acquiring regulatory neurotoxicity data, distinction on whether a toxic agent affects neurons and/or astrocytes is essential. This study evaluated neurofilament (NF) and glial fibrillary acidic protein (GFAP) directed single-cell (S-C) ELISA and flow cytometry as methods for distinguishing cell-specific cytoskeletal responses, using the established human NT2 neuronal/astrocytic (NT2.N/A) co-culture model and a range of neurotoxic (acrylamide, atropine, caffeine, chloroquine, nicotine) and non-neurotoxic (chloramphenicol, rifampicin, verapamil) test chemicals. NF and GFAP directed flow cytometry was able to identify several of the test chemicals as being specifically neurotoxic (chloroquine, nicotine) or astrocytoxic (atropine, chloramphenicol) via quantification of cell death in the NT2.N/A model at cytotoxic concentrations using the resazurin cytotoxicity assay. Those neurotoxicants with low associated cytotoxicity are the most significant in terms of potential hazard to the human nervous system. The NF and GFAP directed S-C ELISA data predominantly demonstrated the known neurotoxicants only to affect the neuronal and/or astrocytic cytoskeleton in the NT2.N/A cell model at concentrations below those affecting cell viability. This report concluded that NF and GFAP directed S-C ELISA and flow cytometric methods may prove to be valuable additions to an in vitro screening strategy for differentiating cytotoxicity from specific neuronal and/or astrocytic toxicity. Further work using the NT2.N/A model and a broader array of toxicants is appropriate in order to confirm the applicability of these methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Endothelial dysfunction and impaired endothelial regenerative capacity play a key role in the pathogenesis of cardiovascular disease, which is one of the major causes of mortality in chronic kidney disease (CKD) patients. Circulating endothelial cells (CEC) may be an indicator of vascular damage, while circulating endothelial progenitor cells (EPC) may be a biomarker for vascular repair. However, the simultaneously evaluation of CEC and EPC circulating levels and its relation were not previously examined in CKD population. A blood sample (18ml) of healthy subjects (n=10), early CKD (n=10) and advanced CKD patients (n=10) was used for the isolation of early and late EPCs, CECs, and hematopoietic cells, identified by flow cytometry (BD FACSCanto™ II system) using a combination of fluorochrome-conjugated primary antibodies: CD31-PE, CD45-APC Cy7, CD34-FITC, CD117-PerCp Cy5.5, CD133-APC, CD146-Pacific Blue, and CD309-PECy7. Exclusion of dead cells was done according to a fixable viability dye staining. This eightcolor staining flow cytometry optimized protocol allowed us to accurate simultaneously identify EPCs, CECs and hematopoietic cells. In addition, it was also possible to distinguish the two subpopulations of EPCs, early and late EPCs subpopulation, by CD45intCD31+CD34+CD117-CD133+CD309-CD146- and CD45intCD31+CD34+CD117-CD133-CD309+CD146- multiple labeling, respectively. Moreover, the identification of CECs and hematopoietic cells was performed by CD45-CD31+CD34-/lowCD117-CD133-CD309-CD146+ and CD34+CD117+, respectively. The levels of CECs were non-significantly increased in early CKD (312.06 ± 91.34) and advanced CKD patients (191.43±49.86) in comparison with control group (103.23±24.13). By contrast, the levels of circulating early EPCs were significantly reduced in advanced CKD population (17.03±3.23) in comparison with early CKD (32.31±4.97), p=0.04 and control group (36.25 ± 6.16), p=0.03. In addition the levels of late EPCs were significantly reduced in both advanced (6.60±1.89), p=0.01, and early CKD groups (8.42±2.58), p=0.01 compared with control group (91.54±29.06). These results were accompanied by a dramatically reduction in the recruitment, differentiation and regenerative capacity indexes in CKD population. Taken together, these results suggest an imbalance in the process of endothelial repairment in CKD population, and further propose that the indexes of recruitment, differentiation and regenerative capacity of EPCs, may help to select the patients to benefit from guiding intervention strategies to improve cardiovascular health by inducing vascular protection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When freshly starved amoebae of Dictyostelium discoideum are loaded with the Ca2+-specific dye indo-1/AM and analyzed in a fluorescence-activated cell sorter, they exhibit a quasi-bimodal distribution of fluorescence. This permits a separation of the population into two classes: H, or ''high Ca2+-indo-1 fluorescence,'' and L, or ''low Ca2+-indo-1 fluorescence.'' Simultaneous monitoring of Ca2+-indo-1 and Ca2+-chlortetracycline fluorescence shows that by and large the same cells tend to have high (or low) levels of both cytoplasmic and sequestered Ca2+. Next we label H cells with tetramethylrhodamine isothiocyanate (TRITC) and mix them in a 1:4 ratio with L cells, In the slugs that result, TRITC fluorescence is confined mainly to the anterior prestalk region. This implies that amoebae with relatively high Ca2+ at the vegetative stage tend to develop into prestalk cells and those with low Ca2+ into prespores. Polysphondylium violaceum, a cellular slime mold that does not possess prestalk and prespore cells, also does not display a Ca2+-dependent heterogeneity at the vegetative stage or in slugs. Finally, confirming earlier findings with the fluorophore fura-2 (Azhar ef al., Curr. Sci. 68, 337-342 (1995)), a prestalk-prespore difference in cellular Ca2+ is present in the cells of the slug in vivo. These findings are discussed in light of the possible roles of Ca2+ for cell differentiation in D. discoideum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Suspensions of testicular germ cells from six species of mammals were prepared and stained for the DNA content with a fluorochrome (ethidium bromide) adopting a common technique and subjected to DNA flow cytometry. While uniform staining of the germ cells of the mouse, hamster, rat and monkey could be obtained by treating with 0.5% pepsin for 60 min followed by staining with ethidium bromide for 30 min, that of the guinea pig and rabbit required for optimal staining pepsinization for 90 min and treatment with ethidium bromide for 60 min. The procedure adopted here provided a uniform recovery of over 80% of germ cells with each one of the species tested and the cell population distributed itself according to the DNA content (expressed as C values) into 5 major classes-spermatogonia (2C), cells in S-phase, primary spermatocytes (4C), round spermatids (1C), and elongating/elongated spermatids (HC). Comparison of the DNA distribution pattern of the germ cell populations between species revealed little variation in the relative quantities of cells with 2C (8-11%), S-phase (6-9%), and 4C (6-9%) amount of DNA. Though the spermatid cell populations exhibited variations (1C:31-46%, HCI:7-20% and and HC2:11-25%) they represented the bulk of germ cells (70-80%). The overall conversion of 2C to 1C (1C:2C ratio) and meiotic transformation of 4C cells to IC (1C:4C ratio) kinetics were relatively constant between the species studied. The present study clearly demonstrates that DNA flow cytometry can be adopted with ease and assurance to quantify germ cell transformation and as such spermatogenesis by analysing a large number of samples with consistency both within and across the species barrier. Any variation from the norms in germ cell proportions observed following treatment, for e.g. hormonal stimulation or deprivation can then be ascribed due to a specific effect of the hormone/drug on single/multiple steps in germ cell transformation

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microfluidic/optofluidic microscopy is a versatile modality for imaging and analyzing properties of cells/particles while they are in flow. In this paper, we demonstrate the integration of fused silica microfluidics fabricated using femtosecond laser machining into optofluidic imaging systems. By using glass for the sample stage of our microscope, we have exploited its superior optical quality for imaging and bio-compatibility. By integrating these glass microfluidic devices into a custom-built bright field microscope, we have been able to image red blood cells in flow with high-throughputs and good fidelity. In addition, we also demonstrate imaging as well as detection of fluorescent beads with these microfluidic devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical microscopy is a versatile and robust tool used for the diagnosis of a plethora of diseases. However, due to various reasons, it remains inaccessible in resource limited settings. In this paper, we present an automated and cost-effective alternative to microscopy for use in clinical diagnostics. With the use of custom optics and microfluidics, we demonstrate a field-portable imaging flow cytometry system. Using the presented system, we have been able to image 586 cells per second. We demonstrate the clinical relevance of the proposed system by differentiating between suspensions of healthy and sphered RBCs based on high-throughput morphometric analysis. The instrument presented here is a major advancement in the domain of field portable diagnostics as it enables fast and robust quantitative diagnostic testing at the point-of-care.